Reer AUSX

TYPE 2 CONTROL UNIT / PLdWEB_01013_AUSX

Download PDF

Type 2 control unit to which it is possible to connect from 1 to 4 safety photocells of the Ilion or Ulisse series, thus forming a Type 2 ESPE having a two-channel relay output and the start/restart interlock and FSD monitoring safety functions.

Conforming to:

– 2006/42/CE Machinery Directive
– 2004/108/CE Electromagnetic Compatibility Directive (EMC)
– 2006/95/CE Low Voltage Directive (LVD)
– IEC/EN 61496-1 Ed. 2.1 Safety of machinery – Electro-
sensitive protective equipment- General requirements
and tests
– IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive
protective equipment – Part 2:Particular requirements
for equipment using Active Optoelectronic Protective Devices
– EN ISO 13849-1 Safety of machinery – Safety-related parts
of control systems – Part 1: General principles for design.
– IEC/EN 62061 Safety of machinery – Functional safety of
safety-related electrical, electronic and programmable
electronic control systems
– IEC 61508 Functional safety of electrical/electronic/
programmable electronic safety-related systems.
– UL (C+US) for USA and Canada

Technical Specifications:

– Up to 4 safety photocells can be connected
– Periodic self test
– Power supply 24 Vdc ± 20%
– Selectable manual or automatic restart
– Monitored restart contact
– 2 NO outputs with safety relays using forced guide contacts
– 1 pnp ´output status´ signalization output
– Beams status and fault diagnosis indicator LEDs
– Feedback input for the control of the machine´s final switching devices
Dimensions h x w x d: 99 x 22,5 x 114 mm
– Provision for fastening to a bar according to Standard EN 50022-35
– Connections with terminal blocks

Model AUSX
Ordering
Code
1201710