Reer ADSRM

TYPE 4 / PL e SAFETY RELAY FOR LIGHT CURTAINS WITH MUTING FUNCTIONWEB_01013_ADSRM

Download PDF

Interface module between the safety light curtains EOS4,
EOS2, Admiral, Vision, the safety laser PHARO and the machine control circuits, with 2-sensor logic integrated Muting.

With guided contact safety relays, 2 NO contacts and PNP output for relay status signaling.

– Start/Restart interlock
– EDM Feedback input for extra external contactors monitoring
– Muting Timeout selectable, 30 sec, 90 min or infinite
– Integrated Override with selectable 2-mode operation
– Muting Enable input.

Conforming to:

– 2006/42/CE Machinery Directive
– 2004/108/CE Electromagnetic Compatibility Directive (EMC)
– 2006/95/CE Low Voltage Directive (LVD)
– IEC/EN 61496-1 Ed. 2.1 Safety of machinery – Electro-
sensitive protective equipment- General requirements and
tests
– IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive
protective equipment – Part 2:Particular requirements for
equipment using Active Optoelectronic Protective Devices
– EN ISO 13849-1 Safety of machinery – Safety-related parts of
control systems – Part 1: General principles for design.
– IEC/EN 62061 Safety of machinery – Functional safety of
safety-related electrical, electronic and programmable
electronic control systems
– IEC 61508 Functional safety of electrical/electronic/
programmable electronic safety-related systems
IEC/TS 62046 Ed. 2 Safety of machinery – Application
of protective equipment to detect the presence of persons

– UL (C+US) for USA and Canada

Technical Specifications:

– Power supply 24 Vdc ± 20%
– 1 two-channel inputs for safety light curtains
2 Inputs for Muting sensors – 24 VDC – PNP or relay – dark-on

24 VDC – PNP or relay muting enable input
2 Safety relay outputs NO – 2A 250 VAC
Safety system status indicator output PNP – 100 mA at 24 VDC
– Selectable manual or automatic restart
– Monitored restart contact
– Inputs and outputs status and fault diagnosis indicator LEDs
– External relay control feedback input, selectable for
external Device Monitoring
– Override function with 2 selectable operating modes
(hold to run and impulse)
– Box dimension h x w x d: 99 x 35 x 114 mm
– Provision for fastening to a bar according to Standard EN 50022-35
– Connections with terminal blocks

Model
Ordering
Code
1330904