TYPE 4 / PL eSAFETY RELAY FOR LIGHT CURTAINS
Download PDF
Interface module between the safety light curtains EOS4 A, EOS2 A, Admiral AD, Admiral AX BK, Vision V and the machine control circuits.
With guided-contact safety relays, 2 NO contacts and PNP output for relay status signaling.
– Start/Restart interlock
– EDM Feedback input for extra external contactors monitoring
Conforming to:
– 2006/42/CE Machinery Directive
– 2004/108/CE Electromagnetic Compatibility Directive (EMC)
– 2006/95/CE Low Voltage Directive (LVD)
– IEC/EN 61496-1 Ed. 2.1 Safety of machinery – Electro-
sensitive protective equipment- General requirements and
tests
– IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive
protective equipment – Part 2:Particular requirements for
equipment using Active Optoelectronic Protective Devices
– EN ISO 13849-1 Safety of machinery – Safety-related parts
of control systems – Part 1: General principles for design.
– IEC/EN 62061 Safety of machinery – Functional safety of
safety-related electrical, electronic and programmable
electronic control systems
– IEC 61508 Functional safety of electrical/electronic/
programmable electronic safety-related systems.
– IEC/TS 62046 Ed. 2 Safety of machinery – Application
of protective equipment to detect the presence of persons
– UL (C+US) for USA and Canada
Technical Specifications:
– Power supply 24 Vcc ± 20%
– Selectable manual or automatic restart
– Monitored restart contact
– 2 NO outputs – 2A 250 VAC
– LED indication of input/output status and diagnosis
– Control feedback input, selectable for external device
monitoring
– Dimensions h x w x d: 99 x 22,5 x 114 mm
– Provision for fastening to a bar according to Standard EN 50022-35
– Connections with terminal blocks
|