Reer ADMIRAL AX

OPTOELECTRONIC SAFETY BARRIERS TYPE 4admiral

Download PDF

Optoelectronic Safety Barrier for the protection of workers exposed to risks arising from the use of dangerous machines. The safety barrier Admiral AX, with its two safe static outputs, can work without external control units with all the safety functions integrated inside the Emitter and the Receiver complying perfectly with the requirments of the European Standard EN 61496-1 and the International Standard IEC 61496-1-2. The Admiral AX integrates the start/restart interlock function as well as the External Device Monitoring (EDM). Master/Slave.

Conforming to:

– 2006/42/CE Machinery Directive
– 2004/108/CE Electromagnetic Compatibility Directive (EMC)
– 2006/95/CE Low Voltage Directive (LVD)
– IEC/EN 61496-1 Ed. 2.1 Safety of machinery – Electro-sensitive protective equipment- General requirements and tests
– IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective equipment – Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
– EN ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design.
– IEC/EN 62061 Safety of machinery – Functional safety of safety-related electrical, electronic and programmable electronic control systems
– IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
– UL (C+US) for USA and Canada
– ANSI / UL 1998 Software in Programmable Components.

Available Models: 4

– resolution 14 and 20 mm for finger detection
– resolution 30 and 40 mm for hand detection
– resolution 50 and 90 mm for presence detection in a hazardous area.
– resolution 90 mm and 2, 3, 4 beams for access control
– Master / Slave (M/S) models for cascade connection of two light curtains

Technical Specifications:

– Selectable maximum scanning distance 6 m or 18 m
– Power supply 24 Vdc ± 20%
– 2 Safety static outputs protected from short circuits and overloads
– Connection with M12, 5 poles connector (Emitter) and M12, 8 poles connector (Receiver)
– Integrated start/restart interlock
– External Device Monitoring (EDM) input
– Master / Slave models
– Floating Blanking (BK models)
– Correct alignment and beam status indicator LEDs
– Seven-segment display for signaling and functional diagnosis
– Suppression of the optical interferences through the range selection
– 3 fastening modes: back slot, side slot or to the top and lower end
– Connection cable length between barriers and safety relay: 50 m
– Accessory deflection mirrors for the realization of perimeter protections along up to 4 sides

Ideal for the protection of:

– Press Brakes
– Presses
– Punching and dinking machines
– Cutters and shears
– Robotic cells
– Assembly lines
– Palletizing system