Reer ADMIRAL AX LR

TYPE 4 INTEGRATED LIGHT GRID WITH LONG RANGE 1629243_admiral

Download PDF

Long Range (60 m) safety light grid for the protection of workers exposed to risks arising from the use of dangerous machines.
The light grid Admiral AX LR has two safe PNP static outputs and can work without any external control unit, having all the safety functions integrated inside the Emitter and the Receiver. It complies perfectly with the requirements of the European Standard EN 61496-1 and of the International Standard IEC 61496-1-2.
The Admiral AX LR integrates the start/restart interlock function as well as the External Device Monitoring (EDM).

AX LR DB / AX LR DB WTH versions featuring an innovative Dual Beam system, useful in outdoor applications and in harsh environments for decreasing the light curtain sensitivity to small objects such as leaves, snow, etc.
Also available in IP 67 heated version with -25 to +55°C op. temp. See IP 67 WATERTIGHT HOUSING

Conforming to:

– 2006/42/CE Machinery Directive
– 2004/108/CE Electromagnetic Compatibility Directive
(EMC)
– 2006/95/CE Low Voltage Directive (LVD)
– IEC/EN 61496-1 Ed. 2.1 Safety of machinery –
Electro-sensitive protective equipment- General
requirements and tests
– IEC/TS 61496-2 Ed. 2 Safety of machinery –
Electro-sensitive protective equipment – Part 2:
Particular requirements for equipment using
Active Optoelectronic Protective Devices
– EN ISO 13849-1 Safety of machinery –
Safety-related parts of control systems – Part 1:
General principles for design.
– IEC/EN 62061 Safety of machinery – Functional
safety of safety-related electrical, electronic
and programmable electronic control systems
– IEC 61508 Functional safety of electrical /
electronic / programmable electronic
safety-related systems.
– UL (C+US) for USA and Canada

Available Models: 1

2, 3, 4 beams for access control
2, 3 beams with DB system

Technical Specifications:

– Maximum scanning distance: 60 m
– Power supply 24 Vdc ± 20%
– 2 Safety static outputs protected from short circuits and overloads
– Connection with M12, 5 poles connector (Emitter) and M12, 8 poles connector (Receiver)
– Integrated start/restart interlock
– External Device Monitoring (EDM) input
– Correct alignment and beam status indicator LEDs
– Seven-segment display for signaling and functional diagnosis
– Suppression of the optical interferences through the range selection
– 3 fastening modes: back slot, side slot or to the top and lower end
– Connection cable length between barriers and safety relay: 50 m
– Accessory deflection mirrors for the realization of perimeter protections along up to
4 sides

Ideal for the protection of:

long distance protection and perimeter protection using defection mirrors (SP and FMC columns)